Satellite System Design Considerations
A. The current release of the AD1024 CPU software/firmware has the following restrictions. Use of these
features is not supported in the current release, and may lead to unexpected system operation.
1. The use of keyboard/user Priority levels is not supported (see Priority menu, System Programming and
Operating Instructions).
2. The Lockout feature is not supported for
REMOTE cameras (see Camera Lockout programming, System
Programming and Operating Instructions).
3. Local alarm monitors can view LOCAL cameras only. If a LOCAL monitor is armed for an alarm contact
(and thus for display of a local camera), do not use that monitor to call REMOTE cameras for viewing.
4. The use of an AD1981 Port Expander with the AD1024 CPU RS-232 ports is not supported for satellite
data links.
5. The use of partitioning for keyboards, monitors, camera viewing and camera control is not supported.
However, keyboards can be partititioned from calling remote sites.
6. Ports used for satellite connections must be set at 9600 baud.
7. The use of an AD1981 Port Expander with the AD1024 CPU RS-232 ports may cause erroneous
information to be displayed in the keyboard. CAMERA display, but will not affect system operation.
B. The adjustment of the on-screen display position and brightness (see Video Selection, page 2-3 and 2-4) is
augmented, as follows, from the instructions in the current AD1024 Matrix Switching Bays Installation
Manual. Reference page 17 of that manual, Video Output Module Horizontal, Vertical, and Brightness
Adjustment, for the following supplemental instructions.
1. Select the monitor to be adjusted.
2. Enter the keyboard codes “5 F2” (enter the number 5, then press the F2 key).
This selects the “Remote Site Title” on-screen display lines, as illustrated in upper lines of Figure 2-2
(page 2-4), for adjustment.
3. On the appropriate Video Output Module (VOM), select the video output position for this monitor (A. . D)
with the rotary switch (see AD1024 Matrix Switching Bays manual, page 17).
For the Remote Site Title lines, position the rotary switch with its white stripe opposite to the
monitor label (e.g., for monitor A, the white stripe is opposite the label “A” on the VOM).
4. Adjust the title
vertical position using the VOM controls, as described in AD1024 Matrix Switching Bays
Manual, page 17 (the horizontal position and brightness is adjusted the same as the Called Camera Title,
below).
5. Enter the keyboard codes “6 F2” (enter the number 6, then press the F2 key).
This selects the “Called Camera Title” on-screen display lines, as illustrated in lower lines of Figures 2-
1 and 2-2 (pages 2-3 and 2-4), for adjustment.
6. On the appropriate Video Output Module (VOM), select the video output position for this monitor (A. . D)
with the rotary switch (see AD1024 Matrix Switching Bays manual, page 17).
For the Called Camera Title lines, position the rotary switch with its white stripe facing the monitor
label (e.g., for monitor A, the white stripe must be facing label “A” on the VOM).
7. Adjust the horizontal position, vertical position, and brightness of this title using the VOM controls, as
described in the AD1024 Matrix Switching Bays manual, page 17.
8. Repeat steps 1 through 7 for each monitor of the VOM and for each VOM, as required.