MONITOR/CONTACT ACCESS
This menu defines which alarm contacts are armed to active
each LOCAL monitor in the system. Refer to the Appendix,
pages A-3 to A-7, for description of Alarm Contact Arming.
Five Monitor/Contact Tables can be programmed by this menu,
providing different Monitor/Contact associations. The first
table, Table 0, is the current (active) system Monitor/Contact
arming status. Monitor/Contact Tables 1 - 4 are stored tables
that can be written into (called to) the current Monitor/Contact
arming table by Event Timers only (page 4-10).
The Monitor Contact Table menu has multiple pages with eight
ACN’s per page vertically, and four monitors per page
horizontally. Refer to page 4-2 for menu paging instructions.
The title line of the menu indicates the table selected for
programming. If two dashes ( - - ) are displayed in this line,
the current (active) table is selected; if a number (1 to 4) is
displayed, the corresponding stored table is selected. The
codes for each entry in the menu are:
Y = ACN is associated to that monitors Arm Type
N = ACN is not associated to the monitor
The above example indicates, for Monitor Contact table 1:
Alarm 3 will activate monitor 3's Arm Type
Alarm 6 or 7 will activate monitor 5's Arm Type
All Monitor/Contact Tables are set default to N.
To select a Monitor/Contact Table for programming:
1. Place the cursor on the menu title line.
2. Enter the table number, 1-4, on the keypad. If no
number is entered, the current active table is selected.
3. Press the ENTER key.
To change the alarm contact associations:
1. Position the cursor to the alarm contact (ACN) and
monitor entry to be changed.
2. Press the ENTER key. Each time the ENTER key is
pressed the setting toggles between:
Y = ACN is associated to this monitor.
N = ACN is not associated.
3. Repeat steps 1 and 2 for any additional changes desired.
4. Position the cursor at the PREVIOUS MENU line.
5. Press the ENTER key to return to the ACCESS Menu.
Note: DO NOT mix monitor salvos in alarm contact arming.
Monitors used for salvo alarms should not be programmed
for individual alarm contacts.
Monitors armed to individual alarm contacts should
not be included in salvos that are armed to alarm contacts
(via the Connect Next or Salvo entries in the Set Alarm
Contacts menu, page 4-12). Such monitors may be armed
to one or more other individual alarm contacts only.
Monitors included in salvos armed to alarm contacts
(via the Set Alarm Contacts menu, page 4-12) should not
be armed to individual alarm contacts. Such monitors
may be included in other salvos armed for alarm contacts,
as long as all salvos are of equal length.
Note: When arming alarm contacts to a monitor block, arm
the contacts to the first monitor of the block only. DO NOT
arm any contacts to the remaining monitors of a block.
Satellite System Note: DO NOT ARM any alarm contacts to
any monitor output which is used as output of a video trunk
line to a REMOTE Site. Alarm contacts can only be armed
to LOCAL monitors.
4-29
AD1024 MENU PROGRAMMING
ACCESS
1. KEYBOARD/MONITOR
2. KEYBOARD/CAMERA VIEW
3. KEYBOARD/CAMERA CTRL
4. MONITOR/CAMERA ACCESS
5. MONITOR/CONTACT ACCESS
6. KEYBOARD/REMOTE SITE
RETURN MAIN
MON CONTACT TABLE - 1
MONITOR
ACN 001 002 003 004
0001 N N N N
0002 N N N N
0003 N N Y N
. NNNN
. NNNN
. YNNN
. YNNN
0016 N N N N