SET EVENT TIMERS
Event Timers permit automatic callup of System Tours and/or
Alarm Monitor/Contact Tables. Each one of the automatic
callups is referred to as an Event.
The EVENT TIMER menu is used to identify and program
LOCAL Events for automatic callups. A maximum of 35
Events may be programming. Each Event can be programmed
for individual System Tour and Alarm Monitor/Contact Table
callups on different days of the week.
An Event Timer (“Event”) is identified by entering a time in
the first line of this menu. If the Event is a new time the word
“NEW” is displayed. If the Event already exists, either the
word “ENABLED” or “DISABLED” is displayed. When the
timer is cleared, the words “ILLEGAL TIME” are displayed.
To create a new Event Timer, or edit an existing Timer:
1. Move the cursor to the time, under the menu title.
2. Enter the hours (e.g., 07) and press the ENTER key.
Note: Enter time in 24-hour format.
3. Enter the minutes (e.g., 11) and press the ENTER key.
The cursor moves to the EDIT TIMER line of the menu.
Note: A maximum of 35 Event Timers can be programmed.
If a time is entered for a 36th event, the message “EVENT
TABLE FULL” is displayed. An existing Event Timer
can be cleared to make room for a newly created table (see
CLEAR TIMER menu command, page 4-11).
EDIT TIMER
Place the cursor on the EDIT TIMER line and press the
ENTER key to display the SET EVENT TIMERS menu. This
menu programs the automatic callups for the Event specified.
The menu has multiple pages with eight monitors per page.
See page 4-2 for cursor movement and paging instructions.
Note: The day of the week must be set properly for Events to
occur as desired. See page 4-4 to set day of the week.
System Tour callup
Each entry in this table identifies a System Tour that is called
at the specified Event time (TIME) for the indicated monitor
(MON) on the indicated DAY OF WEEK. The entries for a
new Event Timer are defaulted to 00, no System Tours called.
To program a System Tour for callup by an Event Timer:
1. Move the cursor to the desired DAY OF WEEK and
MON (monitor) position.
2. Enter the System Tour number (1 - 64) to call to this
monitor at the indicated day and Event time.
Note: Entering 00 is a “no-action” command while 65
is a “hold monitor at current camera” command.
3. Press the ENTER key.
MENU PROGRAMMING AD1024
SYSTEM
1 SET TIME AND DATE
2 SET SYSTEM TOURS
3 SET SYSTEM SALVOS
4 SET EVENT TIMERS
5 SET ALARM CONTACTS
6 SYSTEM OPTIONS
7 MONITOR STATUS
RETURN MAIN
EVENT TIMER
07:11 DISABLED
EDIT TIMER
NEXT TIMER
CLEAR TIMER
ENABLE TIMER
CHANGE TIMER TO HH:MM
PREVIOUS MENU
SET EVENT TIMERS
TIME - 07:11
DAY OF WEEK
MONSMTWTFS
001 01 02 03 04 05 06 07
002 00 00 00 00 00 00 00
003 00 00 00 00 00 00 00
004 00 00 00 00 00 00 00
005 00 00 00 00 00 00 00
006 00 00 00 00 00 00 00
007 00 00 00 00 00 00 00
008 00 00 00 00 00 00 00
ALM0100000