Using the VideoEdge IP Encoder with Intellex IP
_______________________________________________________________________
5
8200-0806-11 B0
Intellex IP CPU Loading
The CPU load on the Intellex IP is determined by all of the configuration settings
but some have more effect than others. Table 2 lists the typical incremental CPU
loading for each of several system settings.
Frames will be
dropped once the
loads exceeds 100%.
Table 2: Incremental CPU load
The greatest CPU load is handling the 240 images per second coming from the
connected encoders. The next highest load is driving the main monitor and
sending images to Network Client. In this scenario it would be possible to receive
240 ips of 4 CIF images, record 120 ips of 4CIF images and either display live on
the main monitor (CPU loading 83%) or display live on Network Client (CPU
loading 83%) but not both (CPU loading 103%). As the CPU load approaches
100% the Intellex IP drops frames being served to the Network Client for live
display and drops frames from recording. Two important things to minimize the
CPU load on the Intellex IP are to 1) configure the encoders to deliver the
minimum live rate necessary for the application, and 2) configure the Intellex IP
with the main monitor disabled if live surveillance is not being done or if live
surveillance is via Network Client. The main monitor can be disabled by enabling
classic security and logging out of the Intellex.